VX-116 Paging Microphone

The Details Related Solution Related Cases Related Video Download


Features  :


* Zone selection button: User can choose single zone, multi zones, or all zones for paging.

* Call button and warning tone button: Press call button when the warning tone button is on, the ring come out firstly.

* Number of rings selection: 2 sounds or 4 sounds.

* Address code setting: After equipment powered on, long press button zone 1 to 6 to set their address code. If in red flashing light, it means the setting is ongoing. Same address code for microphone is not allowed. Address code when press “01” has the highest priority and this microphone can override other microphones.

* Auto standby function: When no signal is detected from mic for one minute, the conversation will close automatically. And the call button is off.

* 24V DC power supply.

* RS485 online port, can be cascaded to 6 pieces.

* MIC/ Chime/ Main volume adjustment.

* Panel is shown with 10 volume levels.

* Microphone support preemptive and queuing function when online use.


Specifications:


Model

VX-116

Mic Type

Condenser microphone

Communication Mode

RS458 control

Capacity

6 ZONE

Output Level

1V/600Ω

Frequency Response

80-16KHz (+1/-3dB )

THD

≤1%

Power Consumption

10W

Communication Distance

1KM

Power Supply

24V DC

Dimension

170x142x54mm

Weight

920g