This series of products is the latest generation of high-power professional digital power amplifiers, featuring high efficiency, stability and excellent sound quality. It is specially designed for large-scale sound reinforcement, performances in multi-function halls, etc.
* Dual-channel high-power professional digital power amplifier;
* The power amplifier has DC, short circuit, overload and overheat protection;
* Adopt variable oscillation modulation technology, multiple feedback control technology and innovative output power control technology to achieve more than 95% ultra-high efficiency and excellent stability;
* Input sensitivity (rated output power@1KHz) optional: 42dB, 39dB, 36dB, 33dB;
* With signal, power, temperature limit function;
* Three modes of MONO/STEREO/BRIDGE can be switched;
* With temperature-controlled fan, which will run when booting, and will accelerate as the temperature increases. The full speed is about 60 degrees;
* The panel has signal indicator (green), clipping indicator (orange), protection indicator (red), and power indicator (blue);
* Regular load is 8 Euros, 4 Euros, and minimum 2 Euros.
Output power (1kHz/THD≤1%) |
Stereo 8Ω: 2*2000W; Stereo 4Ω: 2*3400W; Stereo 2Ω: 2*4760W; Bridge 16Ω: 1*4000W; Bridge 8Ω: 1*6800W; Bridge 4Ω: 1*9520W; |
Connecting socket |
XLR interface |
Input Sensitivity (Rated Output Power, @1KHz) |
42dB,39dB,36dB,33dB,optional |
Input impedance |
10KΩ unbalanced, 20KΩ balanced |
Frequency response (Under @1W power) |
20-20KHz/±1dB |
THD+N (Under @1/8 power) |
≤0.01% |
SNR (A-weighted) |
≥106dB |
Damping Factor (@ 1kHz) |
≥200@ 8 ohms |
Crosstalk (@1kHz) |
≥85dB |
Protection method |
Overvoltage protection, undervoltage protection, overcurrent protection, DC protection, short circuit protection |
Indicator light |
Power, Protection, Signal, Distortion |
Cooling method |
Fan cooling |
Power supply |
~ 220 50Hz |
Overall power consumption |
1700W |
Dimensions (L x W x H) |
484x353x44mm |
Weight |
8.1kg |
Notes: Output power: according to CEA-2006-B/CEA-490-A standard using 20ms pulse 1kHz sine wave measured under 1% total harmonic distortion. Overall power consumption: according to GB4943.1-2022 test method: measured under 1kHz sine wave rated load 1/8 power conditions. |