1.Adopt a 225A main switch and a high breaking air switch with double protection of overload and short circuit.
2. 3-phase independent voltage, current and monitoring; 3-phase A.B.C indicators.
3.Three output modes: 32A bakelite plug, 16A waterproof plug, 19-pin plug.
4.Built-in single-item controllable circuit, can use DMX512 console to control each on/off individually.
|
Power supply |
TN-S system AC 380V±10%, frequency 50Hz±5% |
|
No-load power |
10W |
|
Power factor |
PF≥0.98 |
|
Rated power |
400A Rhino plug input |
|
Rated input current |
Maximum 48 channels × 4kW, suitable for any load |
|
Shell material |
Flight case + cold-rolled plate |
|
Power interface |
5 Rhino plug input interfaces, 48 power output interfaces |
|
Signal interface |
1 DMX512 input interface, 1 DMX512 output interface |
|
Working environment temperature |
-10℃~45℃ |
|
Protection class |
IP20 |
|
Product dimensions (L×W×H) |
605×510×970mm |
|
Packaging dimensions (L×W×H) |
700×620×970mm (Integrated flight case) |
|
Product net weight |
77.3kg |